A blog intended to educate and inform those interested in industrial control instrumentation and process control equipment. Weekly posts on various subjects ranging from pressure / temperature / level and flow instruments, control valves, analytical instruments, drives and actuators, recorders, and process weighing.
For more information, visit the Power Specialties website or call (816) 353-6550
Specializing in Providing Instrumentation and Control Solutions for Industry
Power Specialties provides a wide range of industrial control products, instrumentation, and equipment to a variety of industries including ethanol / biofuel, agricultural and specialty chemical, power, pharmaceutical, manufacturing, and oil and gas production. Products include; flow, level, pressure, temperature, analytical instrumentation, recorders, data acquisition, annunciators, loop controllers, steam jet vacuum systems, process weighing and instrument communications. Visit https://powerspecialties.com.
pH/ORP Measurement for Reverse Osmosis
Reprinted from Yokogawa Application Note AN10B01B20-06E Rev2.
Industry: Refining, Food & Beverage, Power, Oil and Gas, Pulp and Paper, Chemical, Water
Products: pH/ORP and Conductivity Process Liquid Analyzers
Background Information
Click for larger view. |
After preliminary purification which may include filtration, clarification and softening, further downstream, a two-pass reverse osmosis system and demineralization operations are typically employed to further purify the water.
Osmosis is the natural tendency of a fluid, usually water, to pass through a semipermeable membrane from a less concentrated solution into a more concentrated one, thus equalizing the concentrations on each side of the membrane.
In reverse osmosis (RO), pressure must be exerted on the side with the concentrated solution to force the water molecules across the semi-permeable membrane to the fresh (pure) water side.
This semi-permeable membrane inhibits the majority of dissolved impurities from passing through to the pure water side. The amount of impurities carried over depends on the type and condition of the membrane (i.e. age, cleanliness) and the amount of pressure applied (energy) to the process.
Not all the feed water passes through the membrane. Some is diverted to flow over them to cleanse away the rejected impurities in a cross-flow filtration mode.
The RO system produces one purified water stream called permeateand a second stream called concentrate, brine, or reject. Feedwaterenters the machine at fairly low pressure and flows through pre-filters to remove suspended particles, such as silt. Pre-filters are typically a replaceable cartridge type which provides a cost effective method for keeping the membrane clean. Typical life expectancy for these membranes is approximately three years.
RO systems are designed for automatic operation and require routine preventative and corrective maintenance. Common problems include membrane fouling and the use of improper flow rates. The result is reduced throughput capacity and shortened runs.
Membranes can fail altogether, resulting in excessive demand on downstream purification systems and poor quality product water.
Both pH and conductivity measurements are used to safeguard the successful operation of an RO system.
Some types of RO membranes are sensitive to feed water pH and can become damaged if the pH is outside the recommended range of 5 to 8 pH.A pH sensor upstream of the membrane can provide a feedback signal to control dosing of acidic or basic reagent to maintain the pH within acceptable limits.
Conductivity measurements are used at both the inlet and outlet of the RO unit to determine whether the total dissolved solids are being filtered effectively.
General Applications
Reverse osmosis systems can remove up to 100% of suspended solids and approximately 90% of dissolved solids, dissolved silica, alkalinity and hardness.
A common use for RO is for purifying water, removing salts and other impurities to improve the color, taste and other properties. It is regularly used for commercial and residential water filtration and is also one of the methods used for desalinization of seawater.
RO systems are capable of rejecting bacteria, salts, sugars, proteins, particles, dyes, and other constituents which have a molecular weight of greater than 150-250 Daltons.
The separation of ions with reverse osmosis is aided by charged particles. This means any dissolved ions which carry a charge, such as salts, are more likely to be rejected by the membrane than those that are not charged, such as organics. The larger the charge and the larger the particle, the more likely it will be rejected.
The majority of RO membranes are negatively charged when they are operated within the pH levels most commonly encountered in water applications.
Pure Water Applications
A two-pass RO system is typically installed upstream of the demineralizer. Its performance is pH dependent with the second-pass section most dramatically affected. While these changes are not significant in the majority of applications, variations become crucial to the success of high-purity water processing.
In addition, the effect of minor feedwaterconstituents, such as alkalinity and ammonia also play a role in achieving high-purity permeate.
The overall efficiencyof dissolved solids removal is usually determined utilizing a pair of conductivity measurements, one at the inlet (cell 1) and one at the outlet (cell 2). This is referred to as % rejection and calculated by the formula:
% rejection = [1-(cell2)/(cell 1)] x 100
For example if the inlet water had 200 ppm of dissolved solids and the outlet water had 10 ppm, the efficiency would be 95% rejection rate. A typical range for this type of application is 80% -100% rejection.
A final conductivity measurement after the 2nd stage is often used to determine the absolute quality of the outlet water.
Ammonia also affects the production of high purity water and may be present due to municipal chlorination of feed water or from organic contamination.
Ammonia (NH3) will through the membrane system in either the molecular or ionic (NH4+) form.
Click for larger view. |
Ammonium hydroxide is less conductive than ammonium carbonate [(NH4)2CO3] so it is not uncommon to find off-line samples or storage tank water with conductivity higher than that of on-line readings.
The pH values will be lower. This shift in pH is due to absorption of CO2from the air and the formation of carbonic acid in the water. Without the presence of ammonia, this type of contamination of high-purity water with CO2 would generate higher conductivity as well as the reduced pH.
For more information on pH/ORP Measurement for Reverse Osmosis contact Power Specialties by calling (816) 353-6550 or by visiting https://powerspecialties.com.
Swan DIST Water System Distribution Quality Monitors
SWAN Analytical Instrument introduced it's DIST Series Distribution Quality Monitor. The new line offers three options for measuring chlorine, pH, conductivity and turbidity on an easy to install and easy to maintain panel. Versatile output options are available to ensure water quality throughout your distribution system.
Three models are available for continuous monitoring of critical parameters for early warning at wells, pump stations and throughout the distribution system.
All three include pH and conductivity sensors in an easily accessible and easy to service flow cell. They also feature SWAN's non-contact Turbiwell turbidity monitoring.
Complete system comes pre-mounted on panel, ready for operation. Simple 4-20 outputs for each parameter used with SCADA provide an in depth record of water quality. Built in surveillance functions generate alarms if measurement is not valid, such as missing flow, empty reagents, valve and photometer functionality.
For more information, call Power Specialties at (816) 353-6550 or visit https://powerspecialties.com.
Three models are available for continuous monitoring of critical parameters for early warning at wells, pump stations and throughout the distribution system.
- SWAN Dist 1 features reagentless free chlorine measurement.
- SWAN Dist 2 provides colorimetric, DPD based free chlorine measurement.
- SWAN Dist 3 provides colorimetric, DPD based free and total chlorine measurement.
All three include pH and conductivity sensors in an easily accessible and easy to service flow cell. They also feature SWAN's non-contact Turbiwell turbidity monitoring.
Complete system comes pre-mounted on panel, ready for operation. Simple 4-20 outputs for each parameter used with SCADA provide an in depth record of water quality. Built in surveillance functions generate alarms if measurement is not valid, such as missing flow, empty reagents, valve and photometer functionality.
For more information, call Power Specialties at (816) 353-6550 or visit https://powerspecialties.com.
Subscribe to:
Posts (Atom)