Benefits of Thermal Mass Flow for the Measurement of Gases


There are quite a few technologies available to measure flowing gases. When the comparisons are complete, most outcomes point out that thermal mass flow technology is superior to others. This short video explores those benefits and demonstrates why thermal mass flow measurement technology is the right choice for your gas flow measurement application.

Benefits of Thermal Mass Flow Technology:

  • Direct mass flow measurement of air and gases in standard volumetric units (e.g., SCFM or NM3/H) or mass units (e.g., LBS/M or KG/H)
  • No additional pressure or temperature compensation required
  • Repeatability and exceptionally broad measurement range: up to 1000:1 (100:1 typical)
  • Standard linear 4-20mA output proportional to mass flow rate
  • Low pressure drop
  • No moving parts
  • Cost-effective
  • Insertion, Inline & remote* styles
  • Measures flow rate and temperature

Along with these benefits, Fox Thermal improved thermal mass flow with their DDC-Sensor (Digital Sensor Technology). Because of this unique development, Fox Thermal leads the industry for accuracy, quality, and innovative design.

For more information, contact Power Specialties. Call them at (816) 353-6550 or visit their website at https://powerspecialties.com.

Case Study on Thermal Flow Meter Calibration for Natural Gas Service

A study of the importance of gas composition and calibration and their effects on flow meter accuracy.

Errors associated with the calibration of flow meters for natural gas service can be costly but can also be mitigated using an advanced flow meter design that allows field-adjustment of the natural gas composition without loss of accuracy.


Or, read the embedded document below. For more information, contact Power Specialties, Inc. by calling (816) 353-6550 or visit https://powerspecialties.com.




A Simple and Effective Understanding of Laminar Flow and Turbulent Flow

Laminar Flow and Turbulent Flow
Graphic courtesy of Wikimedia.org
Two very important terms to understand when studying flowing fluids are "turbulent flow" and "laminar flow".

Turbulent flow, caused by excessive kinetic energy in parts of a fluid flow, undergoes mixing and lateral irregularities characterized by eddies, recirculation, and apparent randomness. Fluid speed magnitude and direction changes chaotically in turbulent flow.

In contrast to turbulent flow, laminar flow occurs when a fluid flows in parallel "layers" with no interaction between the layers. When flowing at low velocities, fluids tend to flow without lateral (sideways) mixing, and adjacent layers glide past one another, analogous to playing cards sliding between others in a deck.

The video below provides a very simple, but very effective, demonstration of laminar and turbulent flow.

https://powerspecialties.com
(816) 353-6550


Using Orifice Plates to Measure Flow

The orifice plate is the simplest of the flowpath restrictions used in flow detection, as well as the most economical. Orifice plates are flat plates 1/16 to 1/4 inch thick. They are normally mounted between a pair of flanges and are installed in a straight run of smooth pipe to avoid disturbance of flow patterns from fittings and valves.

Three kinds of orifice plates are used: concentric, eccentric, and segmental (as shown in Figure 1).

orifice plate
Fig. 1 - Orifice plates (click for larger view)
The concentric orifice plate is the most common of the three types. As shown, the orifice is equidistant (concentric) to the inside diameter of the pipe. Flow through a sharp-edged orifice plate is characterized by a change in velocity. As the fluid passes through the orifice, the fluid converges, and the velocity of the fluid increases to a maximum value. At this point, the pressure is at a minimum value. As the fluid diverges to fill the entire pipe area, the velocity decreases back to the original value. The pressure increases to about 60% to 80% of the original input value. The pressure loss is irrecoverable; therefore, the output pressure will always be less than the input pressure. The pressures on both sides of the orifice are measured, resulting in a differential pressure which is proportional to the flow rate.
Orifice plate flow pattern
Orifice plate flow pattern (click for larger view)

Differential Pressure Transmitter
Differential pressure
transmitter used to
calculate flow.
(Yokogawa)
Segmental and eccentric orifice plates are functionally identical to the concentric orifice. The circular section of the segmental orifice is concentric with the pipe. The segmental portion of the orifice eliminates damming of foreign materials on the upstream side of the orifice when mounted in a horizontal pipe. Depending on the type of fluid, the segmental section is placed on either the top or bottom of the horizontal pipe to increase the accuracy of the measurement.

Eccentric orifice plates shift the edge of the orifice to the inside of the pipe wall. This design also prevents upstream damming and is used in the same way as the segmental orifice plate.

Orifice plates have two distinct disadvantages; they cause a high permanent pressure drop (outlet pressure will be 60% to 80% of inlet pressure), and they are subject to erosion, which will eventually cause inaccuracies in the measured differential pressure.

Contact Power Specialties with any process flow question or requirement. You can find them by visiting https://powerspecialties.com or by calling (816) 353-6550.

Basics of Rotameters (Variable Area Flowmeters)

Rotameter by Yokogawa
Rotameter (Yokogawa)
A rotameter is a flow measuring device that belongs to a group of instruments called variable area flowmeters. For decades variable area flowmeters have become established in industrial measurement technology with an economical, mature measurement principle.

The variable area flowmeter is an instrument for metering the flowrate of liquids and gases in a pipeline. It includes a vertically oriented conical tube, whose diameter is larger at the top than at the bottom, through which the fluid flows upward and in which a vertically moving float is positioned. The height of the float in the tube increases as the flowrate increases in such a manner that the resistance to the flow is always balanced by the weight of the float and remains constant regardless of the flowrate. The height of the float in the tube is a measure of the flowrate.

The value of the flowrate can be read from a scale. Variable area flowmeters are the most cost effective solution for almost all applications involving the measurement of industrial process liquids, gases or steam. They meet the application requirements by featuring a wide range of design varieties and sizes.

Rotameters offer long life and high reproducibility and are excellent mechanical back-up meters because no external power supply is needed. For more information on rotameters (variable area flowmeters) visit http://www.powerspecialties.com or call Power Specialties at (816) 353-6550.

The video below does a great job introducing the various types and uses for rotameters.

Thermal Flowmeters with Constant Temperature Differential (∆T) Technology to Measure Mass Flow Rate of Air and Gases

Thermal flowmeters use a constant temperature differential (∆T) technology to measure mass flow rate of air and gases. The thermal mass flow sensor consists of two Resistance Temperature Detectors (RTD’s). The sensor elements are constructed of a reference grade platinum wire wound around ceramic mandrels that are inserted into stainless steel or Hastelloy tubes.

The reference RTD measures the gas temperature. The instrument electronics heat the mass flow sensor, or heated element, to a constant temperature and measures the cooling effect of the gas flow. The electrical power required to maintain a constant temperature differential is directly proportional to the gas mass flow rate. The microprocessor then linearizes this signal to deliver a linear 4 to 20mA signal.

One manufacturer, Fox Thermal Instruments, implements a technology they call the Power ProTM Sensor. Their sensor operates at a higher power level than other competitive thermal technologies, providing better response time and wider turndown. When compared to a typical differential pressure type flowmeter, as shown to the right, the Power ProTM sensor offers better low flow or low end sensitivity. The Power ProTM sensor also provides exceptional accuracy at high velocities - up to 50,000 SFPM air.

The Fox DDC-SensorTM is a new state of the art sensor technology used in the Fox Model FT1 Thermal Gas Flow Meter. The DDC-SensorTM, a direct digitally controlled sensor that is interfaced directly to the FT1 microprocessor for more speed and programmability.

Like the PowerProTM Sensor, the DDC-SensorTM accurately responds to changes in process variables (gas flow rate, pressure, and temperature) which are used by the microprocessor to determine mass flow rate, totalized flow, and temperature.

In addition to measuring flow, the DDC-SensorTM provides a technology platform for calculating accurate gas correlations. The FT1 correlation algorithms allow the meter to be calibrated on a single gas in the factory while providing the user the ability to select other gases in the Gas-SelectXTM gas menu. Fox’s Model FT1 with its DDC-SensorTM and state-of-the-art correlation algorithms provide an accurate, multi-gas-capable thermal gas flow meter.

For more information on thermal flowmeters, contact:
Power Specialties, Inc.
9118 E. 72nd Terrace
Raytown, MO 64133
Toll Free: (800) 432-6550
Phone: (816) 353-6550
Fax: (816) 353-1740

Thermal Mass Flow Meters

thermal mass flow meters
Various styles of thermal mass flow meters
(courtesy of Fox Thermal Instruments)
Thermal mass flow meters measure flow by introducing heat into a flow stream and measuring the dissipation of heat between temperature measurement points. They are very popular because they provide a fairly unrestricted flow path, have no moving parts, are accurate over a wide range of flow rates, work well on large or small pipes, don’t require temperature or pressure compensation, and actually calculate mass flow rather than volume. In most cases, thermal flow meters are used to measure and monitor flowing gases, but in some cases they are used to measure the flow of liquids.

Fox Thermal Instruments, located in Marina, CA, manufacturers some of the most innovative and reliable thermal mass flow meters today. Their products are used in a wide variety of industrial gas flow and emissions monitoring applications.

Fox provides three basic models:

Model FT1:
Winner of the 2015 Flow Control Innovation Awards, is the newest Thermal Gas Mass Flow Meter offered from Fox Thermal Instruments.  The Model FT1 was nominated for this award because of its innovative design elements such as the DDC-Sensor™ technology platform that allows it to operate using the Gas-SelectX® gas menu selection tool.

Model FT2A:
The Model FT2A continues to accurately measure gas flow rate in standard units without the need for temperature and pressure compensation. Some additional features available on the FT2A include a standard display, a standard USB port to connect to a PC, and the option of BACnet MS/TP communication protocol.

Model FT3:
The Model FT3 measures gas flow rate in standard units without the need for temperature and pressure compensation.  Calibration Validation, using the CAL-V™ and Zero CAL-CHECK® features, is an in-situ calibration routine that validates the flow meter’s accuracy by testing the functionality of the sensor and it associated signal processing circuitry.

This following brief video quickly presents the specifications and features for each model.