Frac Truck Temperature Transmitters

Frac Truck Temperature Transmitters
Frac Truck
showing temperature
transmitter (REOTEMP)
Frac Trucks pump nitrogen gas into natural gas wells and oil wells to purge remaining fossil fuels that may be imbedded in well bores, slurries, and bedrock. The purged fuels can then be used for commercial use.

Frac Trucks require a variety of sensors to monitor internal components: liquid nitrogen tanks, heat exchangers (used to convert liquid nitrogen to gas), and pumps. Temperature sensors are especially critical on Frac Trucks, because they are used to ensure safe, efficient operations.

Download the PDF version of the "Frac Truck Temperature Transmitters" application note here.

Problem:

The temperature sensors are subjected to continuous shock & vibration during truck operations, from traveling over unpaved roads, and on long highway drives. This shock & vibration was damaging the internal components of the competitor’s transmitters.

The transmitters also operate in a harsh environment, which exposes them to water, mud, and oil. During washdown, the truck is sprayed clean with high pressure water, often causing water to leak into the transmitter’s housing. The water then shorts out the internal components and results in transmitter failure.

Application Challenges 
  • Continuous vibration & shock
  • Harsh environment: oil, water, mud High pressure washdown
  • With frustration, replacements, and downtime increasing

Customer’s Needs:
  • Hermetically sealed: enclosure must not leak under harsh conditions Compact size (space restrictions on truck)
  • Durability: components must withstand continuous shock & vibration
Solution:

REOTEMP designed and engineered a new product called the Slim-Line Transmitter that met all of the customer’s needs. The new product incorporated an all-welded enclosure and re-inforced seals to protect against leaking. A cushioned interior component design ensured the Slim-Line was up to the challenge of the harsh Frac Truck application. This product is now used in a variety of applications that require a very durable, compact, and accurate temperature transmitter.

Reprinted with permission by REOTEMP

CIP Sanitary RTD Sensors

CIP Sanitary RTD Sensors
CIP (clean-in-place) Sanitary RTD Sensors 
General purpose CIP (clean-in-place) sanitary connector RTD temperature sensors are used in processing applications where sensor corrosion and product contamination are critical factors. These sensors must meet or exceed finish specifications set forth by the 3A Sanitary Council Standard.

General-purpose CIP sanitary-connected RTD temperature sensors are used in food, dairy, beverage, pharmaceutical, and chemical processing applications where sensor corrosion and product contamination are critical factors. Sanitary caps are most commonly used in such processes. Sanitary caps are welded to the sheath and to a heavier support tube, all made of stainless steel, and then ground and polished to a finish that exceeds the No. 4 minimum finish required by the 3-A Sanitary Standard 74 - .

Assemblies are supplied with a surface finish that meets or exceeds 32µin Ra. Surface finishes of 15µin Ra or better are available upon request. The process contact surfaces are free of pits, crevices, and pockets thus preventing corrosion and bacteria growth. The 3-wire constructed sensor assembly consists of a high-accuracy platinum element sealed inside a 316 stainless steel sheath, and is provided with a FDA-compliant white thermoplastic gasketed connecting head. The complete assembly provides excellent wash-down protection.

It is recommended that once customer connections are made, the connecting terminals be further protected by applying a coating of moisture-proof sealant over the connections.

For assistance in choosing the right CIP sanitary RTD sensor visit http://www.powerspecialties.com or contact Power Specialties at (816) 353-6550.


Innovative Sensor Design for Mobile Liquid Nitrogen Pump & Vaporizers (MLNPV)

MLNPV Sensor
MLNPV Sensor Location
Reprinted with permission from REOTEMP

Background

MLNPV's are used to pump nitrogen gas into natural gas wells and oil wells. Gas is pumped into the wells to purge remaining fossil fuels which may be imbedded in well bores, slurries, and bedrock. The purged fuels can then be used for commercial use.

Problem: 

The MLNPV's require a variety of sensors to monitor internal components including: the liquid nitrogen tank, heat exchanger (used to convert liquid nitrogen to gas), and the pump. Temperature sensors are especially critical, since they are used to ensure safe, efficient operations.

The MLNPV's were originally outfitted with a gas actuated thermometer which had 30ft of capillary running from the sensor to the dial face located in the control box. The thermometer was subjected to a combination of extreme cold weather and continuous shock/vibration during operation and from traveling over unpaved, off-road paths and long highway drives. This harsh combination lead to continual failures in the field, increasing maintenance costs, downtime, and frustration for the manufacturer as well as the end user.
  • Extreme sensor temperatures to -325F 
  • Ambient temperatures as low as -50F 
  • Continuous vibration & shock 
  • Harsh environment: oil, water, mud 
Considerations: 

The environment and harsh conditions required a sensor that would be extremely robust and still meet the customer's expectations of high accuracy, quick response time, and long life span.

Solution: 

A prototype sensor they believed would meet all of the customers requirements. REOTEMP's design included heavy-duty mil-spec electrical connectors and plastic over-molding to prevent wire damage.

The sensor was put into action and performed extremely well:
  • Able to withstand harsh environment: extreme temperature, oil, water, mud 
  • Improved accuracy 
  • Reduced lead time (to a couple of days) 
  • Lowered cost (by roughly 1/2) 

For more information about REOTEMP Instruments, visit http://www.powerspecialties.com or call (816) 353-6550.

The 2 Most Common Industrial Temperature Sensors

industrial temperature sensors
Thermocouple & RTDs come in many shapes,
styles, and configurations.
This blog post will introduce the reader to the two most common industrial temperature sensors - the thermocouple and RTD (resistance temperature detector).

A thermocouple is a temperature sensor that produces a micro-voltage from a phenomena called the Seebeck Effect. In simple terms, when the junction of two different (dissimilar) metals varies in temperature from a second junction (called the reference junction), a voltage is produced. When the reference junction temperature is known and maintained, the voltage produced by the sensing junction can be measured and directly applied to the change in the sensing junctions' temperature.

Type K thermocouple
Diagram of Type K thermocouple circuit
Thermocouples are widely used for industrial and commercial temperate control because they are inexpensive, sufficiently accurate for many uses, have a nearly linear temperature-to-signal output curve, come in many “types” (different metal alloys) for many different temperature ranges, and are easily interchangeable. They require no external power to work and can be used in continuous temperature measurement applications from -185 Deg. Celsius (Type T) up to 1700 Deg. Celsius (Type B).

As a general rule, industrial thermocouples can be made to withstand higher temperatures and come in a wider variety of thermocouple types. MgO thermocouples are flexible and have wider selection of measurement junction configurations. An MgO thermocouple consists of a thermocouple element encased in a metal sheath and hard-packed with magnesium oxide mineral insulation. Thermocouple sheaths are fully annealed and can be formed into different configurations (minimum bend radius is twice the outer diameter of the sheath). The measuring junction can also be sealed from the environment, reducing the potential for contamination issues.

A typical industrial thermocouple is constructed using an element inserted into a process/environment specific protection tube. In certain configurations, it may be possible to replace the element without removing the protection tube from the process. There are endless combinations of elements and tubes, and are also available separately as replacement parts.
Temperature sensor
Standard industrial temperature sensor configuration
(either thermocouple or RTD)
Common application for thermocouples are industrial processes, the plastics industry, kilns, boilers, steel making, power generation, gas turbine exhaust and diesel engines, They also have many consumer uses such as temperature sensors in thermostats and flame sensors, and for consumer cooking and heating equipment.

RTD’s (resistance temperature detectors), are temperature sensors that measure a change in
resistance as the temperature of the RTD element changes. They are normally designed as a fine wire coiled around a bobbin (made of glass or ceramic), and inserted into a protective sheath. The can also be manufactured as a thin-film element with the pure metal deposited on a ceramic base much like a circuit on a circuit board.

RTD element
Coil wound RTD element
(image courtesy of Wikipedia)
The RTD wire is usually a pure metal such as platinum, nickel or copper because these metals have a predictable change in resistance as the temperature changes. RTD’s offer considerably higher accuracy and repeatability than thermocouples and can be used up to 600 Deg. Celsius. They are most often used in biomedical applications, semiconductor processing and industrial applications where accuracy is important. Because they are made of pure metals, they tend to more costly than thermocouples. RTD’s do need to be supplied an excitation voltage from the control circuitry as well.

RTDs are resistive devices, so lead wire resistance directly affects its accuracy. The error can be quite large, depending on the lead wire resistance (measured in ohms / foot).For example, an uncompensated 2-wire circuit using 30 gauge wires can have an error as high as 1.2°F per foot!Fortunately, there is a method to compensate for the lead wire resistance.

2-wire - One lead wire is connected to each end of the element. This arrangement is suitable for uses where the lead wire resistance may be considered as a constant in the circuit, or where changes in the lead wire resistance due to ambient temperature changes can be ignored.

3-wire - This is the most common of RTD configurations. One lead wire is connected to one end of the element and two lead wires are connected to the other end.The purpose of the third lead is to compensate for the lead wire resistance, thereby increasing accuracy.An instrument capable of utilizing a 3- wire RTD must be used to benefit from this configuration.

4-wire - The most accurate of the RTD configurations, this element uses two wires for each end of the element. Building on the 3-wire concept, compensation is made for the resistance in each lead wire, creating a highly-accurate temperature-measurement device for critical applications.An instrument capable of utilizing a 4-wire RTD must be used to benefit from this configuration.

For more information on temperature sensors, contact:
Power Specialties, Inc.
www.powerspecialties.com
9118 E. 72nd Terrace
Raytown, MO 64133
Toll Free: (800) 432-6550
Phone: (816) 353-6550
Fax: (816) 353-1740