Showing posts with label RTD. Show all posts
Showing posts with label RTD. Show all posts

How to Select and Use the Right Temperature Sensor

After a brief review of how RTD’s and thermocouples are constructed and used to measure temperature, this white paper discusses what differentiates these sensors from one another. You will learn the topics of temperature range, tolerance, accuracy, interchangeability and relative strengths and weaknesses for each type. After reviewing these topics you will have a better understanding as to when each type of sensor should be used and why.

Courtesy of Pyromation and Power Specialties, Inc.


Pyromation: The Premier Manufacturer of RTD Temperature Sensors, Thermocouples & Thermowells In North America


Pyromation is one of the leading manufacturers of thermocouples, RTDs, PT100s and thermowells in North America. As an ISO 9001-registered company, Advanced Manufacturing Firm and Lean enterprise with an onsite NVLAP-Accredited Metrology Laboratory (Lab Code 200502-0), the Fort Wayne, IN-based operation's team members are invested in providing the best solution for each customer's application. Pyromation produces a variety of temperature sensors and assemblies in both standard and custom designs, which can be found on equipment and in process applications in the chemical, petrochemical, power generation, food & beverage, dairy, plastics, heat-treating, oil & gas, pharmaceutical, aerospace, biomass, metal processing, rubber, mining, HVAC, water & wastewater, incineration and many other industries in North America and around the world.

This video provides a short introduction to their capabilities, plant, and people.

Power Specialties, Inc.
https://powerspecialties.com
(816) 353-6550

Super-fast Changeout of Sanitary Temperature Sensor

ReoClick Sanitary Temperature Sensor
Diagram 1
Many BioTech & Pharmaceutical companies test their temperature sensors with in-house calibration baths in order to ensure sensor accuracy. Accurate temperatures are so critical to ensuring a consistent product, that calibration checks are required before each batch is started.

Most existing temperature sensors have a threaded connection which would twist and tangle the extension wires when unthreaded for calibration. The only alternative to unthreading the connection is to disconnect the wires from the terminal. This wastes time and complicates the calibration process.

Manufacturer REOTEMP engineered a great solution. A product named "ReoClick" makes disconnecting and re-connecting the sensor from the process easy. With the click of a button, the temperature sensor is released from the the process, leaving the female adapter in place (see diagram 1). The sensor is then placed into a temperature bath for a quick calibration check and snapped back into service in a matter of seconds.

To make the design even better, REOTEMP incorporated a replaceable temperature element. The element can be easily removed when sensor replacement is eventually needed. This allows the customer to reuse their existing leadwire assembly, male insert, and female adapter (see diagram 2).

ReoClick Sanitary Temperature Sensor
Diagram 2


Along with those cost savings, the customer has avoided the usual headache associated with replacing a competitor’s elements: disconnecting wires, terminal blocks, reconnecting components, etc..

For more information about the ReoClick sanitary sensor, contact Power Specialties by visiting http://www.powerspecialties.com/article_54_REOTEMP.cfm or calling (816) 353-6550.

The Pro's and Con's of Industrial Thermocouples and RTD's

Thermocouples and RTDs are the two most common type of industrial temperature sensors. A thermocouple is a temperature sensor that produces a micro-voltage relative to a temperature change which can be measured, conditioned, and amplified into a standard process signal. RTD’s are temperature sensors that measure a change in electrical resistance relative to the temperature surrounding the RTD element. Each have their advantages and disadvantages, and should be applied understanding their respective strengths and weaknesses.

RTD STRENGTHS:
RTD’s are commonly used in applications where repeatability and accuracy are important considerations. Properly constructed Platinum RTD’s have very repeatable resistance vs. temperature characteristics over time. If a process will be run at a specific temperature, the specific resistance of the RTD at that temperature can be determined in the laboratory and it will not vary significantly over time. RTD’s also allow for easier interchangeability since their original variation is much lower than that of thermocouples. For example, a Type K thermocouple used at 400°F has a standard limit of error of – 4°F. A 100 Ohm DIN, Grade B platinum RTD has an interchageability of – 2.2°F at this same temperature. RTD’s also can be used with standard instrumentation cable for connection to display or control equipment where thermocouples must have matching thermocouple wire to obtain an accurate measurement.

RTD WEAKNESSES:
In the same configuration, you can expect to pay from 4 to 10 times more for an RTD than for a base metal thermocouple. RTD’s are more expensive than thermocouples because there is more construction required to make the RTD including manufacture of the sensing element, the hooking up of extension wires and assembly of the sensor. RTD’s do not do as well as thermocouples in high vibration and mechanical shock environments due to the construction of the sensing element. RTD’s are also limited in temperature to approximately 1200°F where thermocouples can be used as high as 3100°F

THERMOCOUPLE STRENGTHS:
Thermocouples can be used to temperatures as high as 3100°F, generally cost less than RTD’s and they can be made smaller in size (down to approximately .020” dia) to allow for faster response to temperature. Thermocouples are also more durable than RTD’s and can therefore be used in high vibration and shock applications.

THERMOCOUPLE WEAKNESSES:
Thermocouples are less stable than RTD’s when exposed to moderate or high temperature conditions. In critical applications, thermocouples should be removed and tested under controlled conditions in order to verify performance. Thermocouple extension wire must be used in hooking up thermocouple sensors to thermocouple instrument or control equipment. Use of instrumentation wire (plated copper) will result in errors when ambient temperatures change.

SUMMARY:
Both thermocouples and RTD’s are useful instruments for determining process temperature. RTD’s provide higher accuracy than thermocouples in their temperature range because platinum is a more stable material than are most thermocouple materials. RTD’s also use standard instrumentation wire to connect to the measurement or control equipment.

Thermocouples are generally less expensive than RTD’s, they are more durable in high vibration or mechanical shock applications and are usable to higher temperatures. Thermocouples can be made smaller in size than most RTD’s so they can be formed to fit a particular application.

Contact Power Specialties by visiting http://www.powerspecialties.com or calling (816) 353-6550 for more information on temperature sensors.

Abstracted from Pyromation's White Paper "How to Select and Use the Right Temperature Sensor".

Industrial Temperature Sensors and Indicators

Variety of electrical temperature sensors
Variety of electrical temperature sensors (Pyromation)
Temperature sensors are vital to everyday products and in the manufacturing of just about every product we use. Household ovens, refrigerators, and air conditioners all depend on temperature control to function properly and temperature control is essential in all process industries such as chemical, power, refinery, food processing, telecom, cement, fertilizer, pull & paper, plastics and petro-chemical.

Temperature sensors are devices which are used to temperature measurement of a medium (i.e. liquid, solid or gas). The sensor detects change in the temperature, and accordingly, change its physical or electrical property in a manner that can be measured. These sensors come in many different forms and are used for a wide variety of applications.

We as human’s simply sense temperature as hot or cold, but in process control, precise measurement of temperature is required in order to control a process efficiently. Accordingly, the correct temperature sensing device needs to be properly selected.

Types of Temperature Sensors

vapor actuated temperature indicator
Vapor actuated temperature indicator (REOTEMP)
Mechanical temperature sensors and indicators:

Devices that use the physical expansion and contraction of materials (like non-compressable fluids,
vapors, or differential metals) to mechanically open or close a set of contacts.

  • Examples of mechanical temperature sensors are bulb and capillary thermostats, thermometers, mechanical temperature switches, and bi-metallic thermostats.
Electrical temperature sensors:

These sensors undergo a measurable electrical change such as resistance, voltage, or current proportional to a given change in temperature.
Temperature Probe Assembly
Temperature Probe Assembly

  • Examples are thermocouples which generate a micro-voltage based upon a temperature differential between two dissimilar metals; RTDs that increase resistance as the sensing temperature increases; and thermistors,  which dramatically decrease resistance as temperature increases. 
Electrical temperature sensors can be housed in a wide variety of sheaths and/or wells for protection, and come in varying tolerances and accuracies to best suit their intended use.

For more information on temperature sensors, contact Power Specialties at (816) 353-6550 or visit http://www.powerspecialties.com.

CIP Sanitary RTD Sensors

CIP Sanitary RTD Sensors
CIP (clean-in-place) Sanitary RTD Sensors 
General purpose CIP (clean-in-place) sanitary connector RTD temperature sensors are used in processing applications where sensor corrosion and product contamination are critical factors. These sensors must meet or exceed finish specifications set forth by the 3A Sanitary Council Standard.

General-purpose CIP sanitary-connected RTD temperature sensors are used in food, dairy, beverage, pharmaceutical, and chemical processing applications where sensor corrosion and product contamination are critical factors. Sanitary caps are most commonly used in such processes. Sanitary caps are welded to the sheath and to a heavier support tube, all made of stainless steel, and then ground and polished to a finish that exceeds the No. 4 minimum finish required by the 3-A Sanitary Standard 74 - .

Assemblies are supplied with a surface finish that meets or exceeds 32µin Ra. Surface finishes of 15µin Ra or better are available upon request. The process contact surfaces are free of pits, crevices, and pockets thus preventing corrosion and bacteria growth. The 3-wire constructed sensor assembly consists of a high-accuracy platinum element sealed inside a 316 stainless steel sheath, and is provided with a FDA-compliant white thermoplastic gasketed connecting head. The complete assembly provides excellent wash-down protection.

It is recommended that once customer connections are made, the connecting terminals be further protected by applying a coating of moisture-proof sealant over the connections.

For assistance in choosing the right CIP sanitary RTD sensor visit http://www.powerspecialties.com or contact Power Specialties at (816) 353-6550.


Resistance Thermometer Sensor and Thermocouple Data Collection

temperature control
Resistance thermometer sensors (RTSs) and thermocouples are the temperature sensors most widely used in industrial temperature measurement. They have the advantages of simple construction and ease of use, making for convenience in measurement.

However, if correct application methods based on the proper standards are not followed, highly accurate measurements cannot be expected.

This document is a compendium of the basic data relating to resistance thermometer sensors and thermocouples. *This second edition reflects IEC and JIS revisions (thermocouples) of July 1995. We hope that this document will aid you in comparing the various underlying standards from an international viewpoint, and in deciding which standards to follow.

This document also provides information on vital parameters such as operating temperature ranges and tolerances.

The 2 Most Common Industrial Temperature Sensors

industrial temperature sensors
Thermocouple & RTDs come in many shapes,
styles, and configurations.
This blog post will introduce the reader to the two most common industrial temperature sensors - the thermocouple and RTD (resistance temperature detector).

A thermocouple is a temperature sensor that produces a micro-voltage from a phenomena called the Seebeck Effect. In simple terms, when the junction of two different (dissimilar) metals varies in temperature from a second junction (called the reference junction), a voltage is produced. When the reference junction temperature is known and maintained, the voltage produced by the sensing junction can be measured and directly applied to the change in the sensing junctions' temperature.

Type K thermocouple
Diagram of Type K thermocouple circuit
Thermocouples are widely used for industrial and commercial temperate control because they are inexpensive, sufficiently accurate for many uses, have a nearly linear temperature-to-signal output curve, come in many “types” (different metal alloys) for many different temperature ranges, and are easily interchangeable. They require no external power to work and can be used in continuous temperature measurement applications from -185 Deg. Celsius (Type T) up to 1700 Deg. Celsius (Type B).

As a general rule, industrial thermocouples can be made to withstand higher temperatures and come in a wider variety of thermocouple types. MgO thermocouples are flexible and have wider selection of measurement junction configurations. An MgO thermocouple consists of a thermocouple element encased in a metal sheath and hard-packed with magnesium oxide mineral insulation. Thermocouple sheaths are fully annealed and can be formed into different configurations (minimum bend radius is twice the outer diameter of the sheath). The measuring junction can also be sealed from the environment, reducing the potential for contamination issues.

A typical industrial thermocouple is constructed using an element inserted into a process/environment specific protection tube. In certain configurations, it may be possible to replace the element without removing the protection tube from the process. There are endless combinations of elements and tubes, and are also available separately as replacement parts.
Temperature sensor
Standard industrial temperature sensor configuration
(either thermocouple or RTD)
Common application for thermocouples are industrial processes, the plastics industry, kilns, boilers, steel making, power generation, gas turbine exhaust and diesel engines, They also have many consumer uses such as temperature sensors in thermostats and flame sensors, and for consumer cooking and heating equipment.

RTD’s (resistance temperature detectors), are temperature sensors that measure a change in
resistance as the temperature of the RTD element changes. They are normally designed as a fine wire coiled around a bobbin (made of glass or ceramic), and inserted into a protective sheath. The can also be manufactured as a thin-film element with the pure metal deposited on a ceramic base much like a circuit on a circuit board.

RTD element
Coil wound RTD element
(image courtesy of Wikipedia)
The RTD wire is usually a pure metal such as platinum, nickel or copper because these metals have a predictable change in resistance as the temperature changes. RTD’s offer considerably higher accuracy and repeatability than thermocouples and can be used up to 600 Deg. Celsius. They are most often used in biomedical applications, semiconductor processing and industrial applications where accuracy is important. Because they are made of pure metals, they tend to more costly than thermocouples. RTD’s do need to be supplied an excitation voltage from the control circuitry as well.

RTDs are resistive devices, so lead wire resistance directly affects its accuracy. The error can be quite large, depending on the lead wire resistance (measured in ohms / foot).For example, an uncompensated 2-wire circuit using 30 gauge wires can have an error as high as 1.2°F per foot!Fortunately, there is a method to compensate for the lead wire resistance.

2-wire - One lead wire is connected to each end of the element. This arrangement is suitable for uses where the lead wire resistance may be considered as a constant in the circuit, or where changes in the lead wire resistance due to ambient temperature changes can be ignored.

3-wire - This is the most common of RTD configurations. One lead wire is connected to one end of the element and two lead wires are connected to the other end.The purpose of the third lead is to compensate for the lead wire resistance, thereby increasing accuracy.An instrument capable of utilizing a 3- wire RTD must be used to benefit from this configuration.

4-wire - The most accurate of the RTD configurations, this element uses two wires for each end of the element. Building on the 3-wire concept, compensation is made for the resistance in each lead wire, creating a highly-accurate temperature-measurement device for critical applications.An instrument capable of utilizing a 4-wire RTD must be used to benefit from this configuration.

For more information on temperature sensors, contact:
Power Specialties, Inc.
www.powerspecialties.com
9118 E. 72nd Terrace
Raytown, MO 64133
Toll Free: (800) 432-6550
Phone: (816) 353-6550
Fax: (816) 353-1740